Description
Instrument specifications and dimensions
| Technical data | |
|---|---|
| Measuring range | 0–1000 mm |
| Vernier (graduation) | 0.02 mm |
| Vernier scale | 50 divisions over 49 mm |
| Type designation | MAJd |
| Jaw length (d) | 200 mm |
| Min. internal measurement width (e) | 20 mm |
| Recess length (a) | 18 mm |
| Caliper width (c) | 32 mm |
| Slider lock | clamping screw |
| Auxiliary slider | yes |
| Measurement types | external, internal |
| Manufacturer | Varel (Korea) |
Instrument construction and working with large dimensions
Vernier caliper 1000 mm of the MAJd type is a single-sided caliper for external and internal measurements. Read the result from the main scale and the vernier with 0.02 mm graduations — with no batteries or electronics, the instrument is ready for immediate use and unaffected by coolant, dust, or the magnetic field of a machine tool table.
Internal measurements use the same lower jaws — there are no separate upper jaws. The 200 mm jaw length reaches into the workpiece, and the measuring faces on the backs of the jaws measure internal widths as small as 20 mm. The clamping screw locks the slider, allowing you to transfer the measured dimension without risking a change in setting. The auxiliary slider with its screw allows precise jaw positioning without jerking despite the instrument's substantial weight.
With a 0–1000 mm range, technique matters: the workpiece and instrument should be at the same temperature, and the long beam should be supported or handled by two people. Measure without tilting the jaws — over a meter, even slight misalignment noticeably affects the result.
Two functions in a single-sided design
✓ Zero check: before measuring, close the jaws and check that the "0" marks on both scales align.
Reading principle with a numerical example
A vernier with 0.02 mm graduations divides one millimeter of the main scale into 50 parts — 50 vernier marks span 49 mm of the scale. Taking a complete reading involves three steps:
View the scale perpendicularly — reading at an angle causes parallax error
Illustrative diagram — 34.24 mm reading on a caliper with a 0.02 mm vernier
Resolution, maximum permissible errors, and application range
The 0.02 mm graduation specifies reading resolution, not measurement accuracy. Maximum permissible caliper errors increase with the measured length — DIN 862:2015 specifies values for individual ranges and measurement types. In practice, technique also matters: perpendicular viewing, moderate measuring force, and clean measuring faces.
| Vernier | Scale construction | Typical application |
|---|---|---|
| 0.05 mm | 20 divisions over 39 mm | general workshop tasks |
| 0.02 mm This model | 50 divisions over 49 mm | quality control, fits |
DIN 862:2015 specifies the maximum permissible errors for individual lengths and measurement types.
For tolerances below 0.05 mm, a caliper is no longer sufficient — use a micrometer. Measure at a temperature close to 20°C: steel expands by approximately 11.5 µm per meter per degree Celsius, so a workpiece that is 10°C warmer produces an error of approximately 115 µm over a length of 1000 mm.
Vernier caliper 1000 mm with a 0.02 mm vernier is a workshop instrument for workpieces beyond the capacity of a 150 mm caliper: shafts, housings, spacings, and bores. With no batteries or electronics, it remains serviceable for years — it only requires a clean guide and periodic verification of readings.
A 0.02 mm vernier has finer graduations than the 0.05 mm version, making it suitable for checking fits, quality control, and part acceptance inspection alongside general workshop tasks. For tolerances below 0.05 mm, no caliper can replace a micrometer.
Read the whole millimeters on the main scale before the vernier's "0" mark, then find the single vernier mark that aligns with a main scale mark. Multiply its number by 0.02 mm and add it to the whole millimeters, e.g., 34 mm + 12 × 0.02 mm = 34.24 mm.
Insert the measuring faces on the backs of the lower jaws into the bore or groove and open them until they make contact — the smallest measurable dimension is 20 mm. Read the result directly from the scale, just as for an external measurement.
Lock the auxiliary slider on the beam, then use the screw to bring the main jaw up to the workpiece in a smooth, controlled motion. On a long, heavy caliper, this eliminates jerky movements that distort the measurement result.
No customer reviews for the moment.
All orders are delivered by courier company GLS. For orders exceeding 369 PLN gross shipping is FREE
| Courier GLS | Przelew24 / Prepayment | 14,76 zł gross | Delivery time 1 working day |
| Courier GLS | Cash on delivery | 17,26 zł gross | Lead time 1 working day |
Użyj strzałek, aby zmieniać zdjęcia. Powiększaj przyciskami albo gestem szczypania. Zamknij galerię klawiszem Escape.
This website uses its own and third-party cookies to improve our services and show you advertising related to your preferences by analyzing your browsing habits. To give your consent to its use, press the Accept button.