Outside micrometer 275–300 mm – 0.01 mm resolution
Technical data and instrument construction
| Technical data | |
|---|---|
| Measuring range | 275–300 mm |
| Resolution | 0.01 mm |
| Measuring face flatness | 0.006 mm |
| Measuring tips | cemented carbide |
| Ratchet force | 5–10 N |
| Micrometer screw pitch | 0.5 mm per revolution |
| Spindle lock | yes |
| Included | adjusting wrench, 275 mm setting standard |
MMZb outside micrometer – construction and applications
Applications for an instrument with this measuring range
Outside micrometer 275–300 mm is an analog instrument with a resolution of 0.01 mm for checking medium-sized external dimensions. The bow-shaped frame (designation MMZb) has a larger opening, allowing the instrument to accommodate workpieces that cannot be measured with a basic-range micrometer. The micrometer screw with a pitch of 0.5 mm provides 50 divisions of 0.01 mm per thimble revolution.
The cemented carbide measuring tips maintain a flatness of 0.006 mm even under heavy use. The ratchet maintains a measuring force of 5–10 N, so the result does not depend on the operator's hand force. The spindle lock holds the reading while it is read. DIN 863 defines the accuracy of micrometers in this class; with this frame opening, frame rigidity is also important to limit deflection under measuring force.
Typical applications:
- measuring the diameters of shafts, sleeves, and bearing journals in the 275–300 mm range,
- checking dimensions after turning and grinding before assembling mating parts,
- measuring the thickness of housings, flanges, and welded components,
- in-process and acceptance inspection in machining departments.
How to read the measurement
Sleeve and thimble scales step by step
The result consists of two readings. Whole and half millimeters are read on the sleeve — the whole-millimeter marks are below the reference line, and the 0.5 mm marks are above it. Hundredths of a millimeter are read on the thimble at the reference line. In the illustrated example, the thimble edge has passed the 87.5 mark, and the reference line indicates division 32, giving a result of 287.82 mm.
Steel expands by approximately 11.5 µm per meter for a temperature change of 1°C. A workpiece with a diameter of 300 mm that is 5°C warmer than the instrument is approximately 0.017 mm larger. The workpiece and micrometer should therefore be at the same temperature, preferably close to 20°C.
Do not tighten the spindle beyond the ratchet's slipping point
Excessive force distorts the result and can permanently deform the measuring faces. Turn only the ratchet knob until it starts to slip, then hold the reading with the spindle lock.
Micrometer precision in figures
Parameters relevant to workshop tolerances
Set contents and zero setting
Preparing for the first measurement
Before measurement, set the instrument's zero using the included 275 mm setting standard: close the tips onto the standard using the ratchet and check that the scale reads exactly 275.00 mm. Correct any deviation by rotating the sleeve with the adjusting wrench.
Measuring with a micrometer step by step
Procedure for repeatable results
Four steps to a repeatable result
standard: 275 mm
force: 5–10 N
lock reading
resolution: 0.01 mm
Full reading: sleeve and thimble readings plus the full hundreds of millimeters in the range (200 mm).
The 275–300 mm outside micrometer combines a simple, reliable analog design with a resolution of 0.01 mm. Carbide measuring tips, constant ratchet force, and a spindle lock ensure repeatable results over years of use. It is essential equipment for quality control stations wherever outside diameter measurement must be more reliable than with a caliper.
Frequently asked questions
Add the sleeve reading (whole and half millimeters) to the thimble reading (hundredths of a millimeter). Remember to add the full hundreds of millimeters for the range: in the illustrated example, 200 + 87.50 + 0.32 = 287.82 mm.
Steel expands by approximately 11.5 µm/m for every 1°C. A workpiece a few degrees warmer than the instrument is larger by a few hundredths of a millimeter, making a 0.01 mm reading meaningless. Measure after the temperatures have equalized, preferably at approximately 20°C.
The set includes an adjustment wrench for adjusting the sleeve and a 275 mm setting standard for setting the zero point. Store the instrument with the measuring faces slightly apart.
Reviews
No customer reviews for the moment.
Shipping
All orders are delivered by courier company GLS. For orders exceeding 369 PLN gross shipping is FREE
| Courier GLS | Przelew24 / Prepayment | 14,76 zł gross | Delivery time 1 working day |
| Courier GLS | Cash on delivery | 17,26 zł gross | Lead time 1 working day |
Recommended for you
Outside micrometer 900-1000 mm 0.01 mm Mitutoyo
Użyj strzałek, aby zmieniać zdjęcia. Powiększaj przyciskami albo gestem szczypania. Zamknij galerię klawiszem Escape.
This website uses its own and third-party cookies to improve our services and show you advertising related to your preferences by analyzing your browsing habits. To give your consent to its use, press the Accept button.