Try square with base 600x300 – steel 90° square
Technical data for KINEX 4034-22-060, grade 2
| Technical data | |
|---|---|
| Standard | DIN 875, form B |
| Accuracy grade | 2 (DIN 875/2) |
| Long arm H | 600 mm |
| Short arm L | 300 mm |
| Arm cross section a × t | 50 × 10 mm |
| Base b × c | 40 × 8 mm |
| Perpendicularity tolerance | 0.080 mm |

KINEX manufactures try square with base 600x300 in grade 2 according to DIN 875 – the standard for steel 90° squares. Perpendicularity deviation does not exceed 0.080 mm over a length of 600 mm. The 40 mm base, 4 times wider than the arm, provides a stable reference on a surface plate and support against the workpiece edge.
The 600 × 300 mm size is not listed in the DIN 875 table – the manufacturer adds it between 500 and 750 mm. The tolerance is calculated using the same formula from the standard.
Workshop try square with base in practice
Four tasks, one precision instrument
Checking perpendicularity against the light
Stand the square on its base on a surface plate and move the 600 mm arm against the workpiece face without applying pressure. Position a lamp behind the contact and view the contact line from the front.
✓ Result: no light gap over the full height indicates a deviation below the method's visibility threshold. A wedge of light at the top or bottom shows the direction in which the face deviates from 90°.
Measuring the gap with a feeler gauge
Insert the blades into the widest part of the gap, starting with the thinnest. The thickest blade that enters without pressure indicates the gap size.
✓ Result: a result in hundredths of a millimeter – starting at 0.03 mm, the thickness of the thinnest blades in the sets.
Scribing a perpendicular line with a layout square
The base projects 15 mm below the plane of the arm. Lay the square flat, press the base against the reference edge, and guide the scriber along the arm.
✓ Result: a line at 90° to the edge, repeatable with each placement. This is how a layout square with a base works.
Workpiece corner and shoulder
Place the internal angle around the external corner of the workpiece. Use the external angle to check a shoulder: the base rests on the bottom, and the arm contacts the face.
✓ Result: DIN 875 applies the perpendicularity tolerance to both the internal and external angles. The corner relief prevents the workpiece edge from bearing against the square.
Grade 2 precision try square with base – what 0.080 mm means
Tolerance zone, calculation, and grade selection
Perpendicularity tolerance is a zone, not a "plus or minus" deviation. Its width for grade 2 is given by the DIN 875 formula.
t = 20 + 600 / 10 = 80 µm = 0.080 mm
t – perpendicularity tolerance for grade 2 per DIN 875: 20 µm plus one tenth of the arm length in millimeters (1 µm = 0.001 mm). In angular terms, this is approximately 28″, less than one angular minute (″ – angular second, 60″ = 1 minute). At a height of 600 mm, the arm may deviate from perfect vertical by no more than 0.08 mm.
Perpendicularity tolerance of the 600x300 square per DIN 875
| Arm length | Grade 0 | Grade 1 | Grade 2 |
|---|---|---|---|
| 75 mm | 0.007 mm | 0.014 mm | 0.028 mm |
| 100 mm | 0.007 mm | 0.015 mm | 0.030 mm |
| 150 mm | 0.008 mm | 0.018 mm | 0.035 mm |
| 200 mm | 0.009 mm | 0.020 mm | 0.040 mm |
| 250 mm | 0.010 mm | 0.023 mm | 0.045 mm |
| 300 mm | 0.011 mm | 0.025 mm | 0.050 mm |
| 400 mm* | 0.013 mm | 0.030 mm | 0.060 mm |
| 500 mm | 0.015 mm | 0.035 mm | 0.070 mm |
| 600 mm* | 0.017 mm | 0.040 mm | 0.080 mm This product |
| 750 mm | 0.020 mm | 0.048 mm | 0.095 mm |
| 1000 mm | 0.025 mm | 0.060 mm | 0.120 mm |
Note: perpendicularity tolerance is the zone width referenced to the underside of the base, not a "±" deviation. Values apply at 20 °C. Grade 00 applies only to knife-edge squares. * Length not listed in the DIN 875:1981 table – value calculated using the standard's formula.
Arm flatness tolerance per DIN 875
| Arm length | Grade 0 | Grade 1 | Grade 2 |
|---|---|---|---|
| 75 mm | 0.003 mm | 0.006 mm | 0.011 mm |
| 100 mm | 0.003 mm | 0.006 mm | 0.012 mm |
| 150 mm | 0.004 mm | 0.007 mm | 0.014 mm |
| 200 mm | 0.004 mm | 0.008 mm | 0.016 mm |
| 250 mm | 0.005 mm | 0.009 mm | 0.018 mm |
| 300 mm | 0.005 mm | 0.010 mm | 0.020 mm arm L |
| 400 mm* | 0.006 mm | 0.012 mm | 0.024 mm |
| 500 mm | 0.007 mm | 0.014 mm | 0.028 mm |
| 600 mm* | 0.008 mm | 0.016 mm | 0.032 mm arm H |
| 750 mm | 0.010 mm | 0.019 mm | 0.038 mm |
| 1000 mm | 0.012 mm | 0.024 mm | 0.048 mm |
Note: flatness and straightness apply to each arm separately – the green rows represent arm H and arm L of this square. Side faces of the arms: 6 × the tabulated value. Values apply at 20 °C. * Length not listed in the DIN 875:1981 table – value calculated using the standard's formula.
The workpiece tolerance should be at least 4 times, and preferably 10 times, the instrument tolerance. For 0.080 mm, this gives 0.32 mm (1:4) and 0.8 mm (1:10). The try square with base 600x300 can therefore reliably assess perpendicularity with a tolerance of 0.8 mm or greater, or 0.32 mm or greater under the 1:4 rule.
How to check perpendicularity with a steel try square with base
The light gap method step by step
Inspection with a workshop square in 4 steps
the square and workpiece, remove burrs from the edges
the base on a surface plate or on the workpiece datum surface
the arm against the face being checked without applying pressure
the gap against the light, and its width with a feeler gauge
The underside of the base is the measurement datum.
Do not tilt the square to contact the workpiece with only the edge of the arm. DIN 875 prohibits using flat squares and try squares with bases this way; a knife-edge square is used for edge-based inspection. The absence of a light gap does not prove that the workpiece is within its tolerance – only that the deviation is below the method's detection threshold.
The try square with base 600x300 is a precision square for daily right-angle checks at the machine tool and on the layout plate. Grade 2 per DIN 875 distinguishes it from workshop squares that have no accuracy grade or specified tolerance. Store it in its case, away from the floor and sunlight, because the standard's tolerance applies at 20 °C.
Questions about the try square with base
Grade, tolerance, calibration
A flat square (form A per DIN 875, designation MKSa) is a flat L shape. A try square with base (form B, designation MKSc) has a base under the short arm that is wider than the arm: here, 40 mm compared with an arm thickness of 10 mm. The base allows the square to stand unsupported on a surface plate and rest against the workpiece edge during layout work.
No. 0.080 mm is the tolerance zone width: the distance between two parallel planes perpendicular to the base. The measuring surface of the arm must lie between them. The "±" notation suggests a deviation of 0.080 mm in each direction, meaning a zone twice as wide.
A grade 2 precision try square with base per DIN 875 is used for layout work, setting up workpieces on machine tools, and checking perpendicularity in production. With a 600 mm arm, it permits a deviation of 0.080 mm, so the square can reliably assess workpiece perpendicularity with tolerances of approximately 0.32 mm or greater – the workpiece tolerance is then at least 4 times the instrument tolerance.
Squares are not subject to legal metrological control in Poland, so legal verification does not apply. Calibration is voluntary, and its frequency is determined by the user, for example within a quality system. After a drop or impact, check perpendicularity before further use.
Reviews
No customer reviews for the moment.
Shipping
All orders are delivered by courier company GLS. For orders exceeding 369 PLN gross shipping is FREE
| Courier GLS | Przelew24 / Prepayment | 14,76 zł gross | Delivery time 1 working day |
| Courier GLS | Cash on delivery | 17,26 zł gross | Lead time 1 working day |
Recommended for you
Użyj strzałek, aby zmieniać zdjęcia. Powiększaj przyciskami albo gestem szczypania. Zamknij galerię klawiszem Escape.
This website uses its own and third-party cookies to improve our services and show you advertising related to your preferences by analyzing your browsing habits. To give your consent to its use, press the Accept button.